AREVA
01dB Brasil > PRODUTOS NVH > Aplicações > Materiais > Pro-515 - Absorção Acústica

PRO-515: Acoustic Absorption

Getting characteristics of Porous Materials

NetdB-PRO-515: Kundt Method for porous materials!
A complete system for getting the absorption characteristics of porous materials, using the Kundt method complying with ISO-10534 and ASTME E-1050 standards.

The PRO-515 system is composed of:

  • 2 Kundt tubes of different sizes both holding a wideband acoustic plane wave source
  • ¼'' microphones and adjustable samples holder
  • Internal (Symphonie) or external noise generator
  • 2-way wideband power amplifier/booster  

Together with a Windows-based dedicated software, PRO-515 allows easy and reliable measurement of the acoustic absorption "∧" coefficient of porous materials

Key Features    

Standard compliant and Expandable

  • 2 Kundt tubes of different diameter sizes (28mm and 100mm respectively) according to ISO1053 and ASTM E-1050
  • Samples length up to more than 40 cm
  • Improve precision by using 2 independent tubes and heavy Alu-based tubes construction
  • Kundt tubes pair upgradeable for TL measurement
  • Alternative methodology available for poro-acoustic materials characteristics based on Impulse response technique  

Easy to operate and flexible

  • User friendly software interface leading up to completion of the measurement
  • Typical application for Laboratory use
  • Also portable and battery operable
  • Easy calibration in amplitude and phase for microphone pairs  

Options

  • Upgrade to PRO-516 for TL measurements from TF method
  • Upgrade to PRO-517 for increased accuracy in parameters determination using on Impulse Response for: Alpha and Zc complex (energy based method)

Applications

Applicable to Porous, Multi-layers, Sandwich materials in: Automotive, Aeronautics, Railway, Ship, Construction Machines, Building construction.

 

PRO-515 Technical Specifications

Signal input

  • Input impedance: 1 Megohms
  • Input connection: DC o AC (da 0,3 o 10 Hz +/ - 10 %); LEMO 7 pin
  • Signal conditioning: Microphone Preamplifier (28V-10mA), Polarization Voltage (0-200 V), IEPE(4.3 mA), Direct Input
  • Tacho input: Auxiliary Input
  • Max voltage input: 20 V p-p, Overload protection
  • Channels: < 0.1° with same gain on both channes, < 0.5° if different gain
  • Phase Filtering: HiPass filter (0.3/10 Hz)

A/D Convertor

  • Resolution: 18 bits sigma/delta.
  • Sampling: 51.2 kHz max.
  • Antialiasing: Butterworth, 120dB/octave
  • Offset: Automatic
  • Signal/Noise ratio: > 90dB
  • Amplifiers: up to 65 dB in 1 dB step600MHz

Analog Output

  • Type: 1-2 channels output syncronized with acquisition
  • Sampling: From 100 Hz to 51.2 kHz
  • Connection: LEMO 4 pin
  • Converters: 18 bits
  • Max Voltage output: 5 V p-p

Dimensions

  • Dimensions: 85 x 35 x 220 mm
  • Weight: 500 gr

Digital I/O

  • Connections: 2 inputs and 2 ouputs
  • Processors: TMS320C31 + TMS320C203
  • Performance: 100 MFLOPS
  • Precision: 32 Bits
  • SRAM: 128K x 32 bits
  • RAM: 16Kb double access
  • Connector: Mini Dyn (PS/2 )

Power supply

  • Power supply type: PC powered PCMCIA card

Microphone Cartridge

  • Type: ¼'' Pressure
  • Sensitivity: 4mV/Pa
  • Freq. Range (±1dB): 10Hz - 40kHz
  • Polarisation voltage: 200V
  • Capacitance: 7pF
  • Calibration certificate : included

Plane Wave Loudspeakers

  • Rated Power: 50W
  • Coil Impedance: 4 ohm
  • Freq. Range (±3dB): 100Hz - 15kHz
  • Resonant Freq.: 70Hz
  • Source Diameter: 130mm

Noise Generator

  • Noise spectrum: White - Pink
  • Crest Factor: >3.3
  • Bandwidth: 10Hz - 40kHz
  • Output Level: 0dB (re 1Vrms); -10dB; -20dB
  • Output Impedance: 50 ohm

Power Booster

  • Rated Power (2x4 ohm load): 2x22W
  • Freq. Range: 1Hz - 150kHz
  • Total Harmonic Distortion: <0.1%
  • Hi-pass Filter: 31.6Hz - 100Hz
  • Lo-pass Filter: 5kHz - 20kHz

Mechanical Elements

  • Frequency Response:
    (28mm Tube): 450Hz - 7100Hz
    (100mm Tube): 50Hz - 1800Hz
  • No-Sample Absorption (Tube 28 / 100 mm): <2% / <3%
  • Source - Sample Distance (Tube 28 / 100 mm): 165 / 550 mm
  • Sample Length (Tube 28 / 100 mm): up to 250mm
  • Device Weight (28 / 100): approx. 6 / 17 kg
  • Height x Depth (both devices): 260 x 250 mm
  • Length (no sample) (28 / 100): 700 / 1165 mm

Software

  • Platform: MS Windows '98 / 2000 / XP
  • Graphical User Interface: Simple 2 level menu
  • Kundt Device Calibration: Message driven
  • Freq. Sub-Ranges: User selectable
  • Frequency Sub-Ranges Linking: Available
  • Acquisition parameters: User selectable
  • Absorption coefficient "alpha":Automatically computed
  • Graphical Data Rendering: FFT or 1/3 octave
  • Multiple Data Superimposing: Available
  • Database Type: Native, user selectable
  • Data Export Format: text file
  • Report Printout: Standard available

Microphone Preamplifier

  • Size: ¼''
  • Freq. Range: 2Hz - 200kHz
  • Noise (Lin): <6µVRMS
  • Body Length: 43mm
  • Cable length: 2m
  • Connector: Lemo 7 pin male

* IEPE: Integrated PiezoElectric Electronic

Ordering Information:

SSP3002000: Symphonie 2 channel inputs Lemo 7 - 2 channel outputs - PCCARD Interface
G-40BP: ¼'' Pressure Microphone
G-26AC: ¼'' Microphone Preamplifier with Integral Cable 2m
M-V11: Power Booster with HP - LP Filters
M-G10: Noise Generator
M-AR42OK: 12V DC System Power Supply / Four Module Holder
ALIM-AT3: 220V AC/12V DC 3A Main Adapter
SS000/1-SET: High Quality BNC Interconnection Cable Set (3x1m)
dBAlphatest: Software Package for alfa coefficient (Win98 / 2000 / XP)
SCS9020B: 2 Kundt Tubes sizes f28x165mm and f100x600mm), 2 Adjustable Sample Holders  sizes f28x250mm and f100x90mm

Para mais informações, nós contatar : comercial@01db.com.br

Mapa do Site | Atualizações | Menções Legais
© Copyright 2012 - ACOEM

Medições e Analise de Ruidos e Vibrações