PRO-250: Sound Power with ISO 3741/4/5/6
Get the sound power of your products!
NetdB-PRO-250: Sound Power measurements on a 12 channel basis Equivalent to NetdB PRO-265 an optimized price for interfacing with your own set of microphones.
To make an easy job of sound power measurement according to ISO3741 in reverberant room, ISO3744 in normal rooms, ISO3745 in semi anechoic and anechoic environment, ISO3746 in external open space, our PRO-250 12ch system offers the ideal turn-key solution: Battery operated User oriented Graphical Interface High measurement/calculation capabilities in a few clicks Remote control operations most relevant for very low noise measurement conditions

Key Features
Automatic measurement and Reporting - Measurement of Background level, SPL, Power level
- Data Reloading and editing at any time
- Curves copy/paste
- Word Label for certification
- Multi-channel Data storage in a specific Data base
- All data: sound pressure, background, power levels possibly exported in HTLM format
- Word report and certification label document
A complete set of tools for data management - Full Predefined measurement configurations for each standard
- Pre definition for number of microphones, meshing, extra-sensors
- No need to read the full documentation to launch the first test.
- Sensors distribution automatically managed during the acquisition
- Reverberation data input
- Create measurements sequence w/out individual weighting coefficients
Options - Multi-channel Sound power in reverberant rooms
- Moving sources according to CE2000/14
- Tonality and impulsiveness following the ISO7779 and ECMA074 standards
Applications
Industrial Machineries manufacturers, Research laboratories, Industrial consulting offices, Certification authority, Construction Machines, Household appliances
PRO-250 Technical Specifications
NetdB-DAQ12 Hardware - PC Link (Type/seed): Ethernet 100MBits connector RJ45 and 2 x USB II sockets (Rear panel)
- PDA Link (type/seed): WiFi 802.11g 54Mbits for remote control
- Storage: 100 GB HDD (12 hours of continuous measurement @ 12 channels 51.2KHz 24bit)
- Base channel numbers: 4, 6, 8, 10, 12 up to 127
- Maximum throughput rate: 12 channels units can be chained12 Channels @ 51.2kHz 24bit on each NetdB-DAQ12
- Channel input connectors: BNC with high rigidity frame
- Signl output: 2 x BNC connectors
- Digital Input/Output: RCA connector for SPDIF In/Out
- Digitization: 24 bits linear
- Sampling Frequency: 51.2kHz, 25.6kHz, 12.8kHz, 400Hz
Analog input Characteristics - Input impedance: 1MOhms
- Input range: 10V, 1V, 100mV rms
- Maximum allowable voltage: -20/+30V peak
- Sensor power supply: IEPE & TEDS (IEEE1451.4) compliant
- Anti-aliasing low-pass filter cut: DC, AC 0.3 Hz, AC 20 Hz
- Dynamic range: 105dB
- External trigger: BNC connector
Power supply - Battery: Internal NiMH 4000mAH, 1H45 continuous operation 12 channels
- Main adaptor: External Main Adaptor 100/240VAC - 50-60 Hz
- Power consumption: 20W
- Car adaptor supplied: DC 9-18V with jack
Environmental - Operating temperature: 0°C to 60°C
- Storage temperature/humidity/Pressure: -10 to 50°C, 10 - 90% RH (no condensation), 500 - 1060 hPa
- Operating position: Horizontal and Vertical
- Vibration resistance: 10ms-2 (9-200Hz), 3mm (2-9Hz) operating
- Shock resistance: 250ms-2 (2ms) operating
- Vibration class: EN60721-3-4 class 4M5
- Noise emission: LWA 49dBA with fan running, LWA 33dBA fan off, software selectable (ISO7779)
- EMI: EN55011, EN55014, EN61000-4.2, EN61000-4.3, EN61000-4.4, EN61000-4.5, EN61000-4.6, EN61000-4.11
- Safety: UL3101-1; CSA C22.2 No.1010.1; EN 61010-1 A1+A2
Computer (min. configuration) - OS: MS Windows XP PRO
- PC Processor: Pentium II+, 600+ MHz
- RAM: 512+ Mb
- Ports: Ethernet
Physical - Dimensions: 250mm(W) x 85mm(H) x 263mm(D) excluding projections
- Weight: 3.5kg
Standards supported: ISO3741 for reverberant rooms, ISO3745 for semianechoic rooms, ISO3744 and ISO3746 for semi anechoic non prepared rooms and free field conditions. Printed results and export of diagrams and numerical values in most common Windows forms Spectral analysis with consistent filters. Customizable Report.
Operational capabilities: Follow Wizard for a fast definition of the tests configuration, Define automatic and specific meshing, Use of customized reverberation laws, Create sequence of measurement, Apply weighting coefficients on each sequence, Switch between the tests results for easy comparisons, Calibration (manual and automatic modes), Dynamic range control.
Database & Export capabilities: Creation of a tests database, Background level, SPL Power level, Any results exportable in HTML format, Curves copy/paste, Word Label for certification, Word report: information on test conditions, measured values of pressure (SPL, background noise) and the power level
Data edition: SPL on each microphone (global LIN & A, versus frequency); Average SPL (global LIN & A, versus frequency); D Level between the SPL and the background noise (global LIN & A, versus frequency); Sound power (global LIN & A, versus frequency) 1/3 octave and narrow band spectra.
Graph display: Curves versus frequency; Global values (LIN, A); Cursors; Curves superimpositions
Software options: ISO3741 for reverberant rooms; CE2000/14 for pass-by power in outdoor conditions; ECMA074 and ISO7779 for tone and impulse detection
Ordering Information:
NDB1002000: NetdB12 unit composed of 12 channels acquisition front-end, AC/DC/IEPE inputs, 2 generators, headphones and SPDIF outputs, Patented Ethernet protocol, 60GB hard disk. SFA4067000 / SFA4073000: dBFA-POWER: Sound Power Software Multiple Channel Support - with one license up to 12 channels - 1/3 octave and parallel signal recording - Manual Reverberation Time data input - Automatic calibration sequence - includes ISO3744, ISO 3745 and ISO 3746 SP Measurements. Transducers and accessories: Up to 10 microphone sets assumed as part of your own test equipment. This hardware is delivered within a dedicated package of the NetdB Pro-Series:
|
|