AREVA
01dB Brasil > PRODUTOS NVH > Sistemas de analise > Intensidade Sonora > Pro-280 - Potencia Sonora ISO9614 - 2 canais PRO117 (dB4)

PRO-280: Sound Power / ISO 9614

Sound Power fitting ISO 9614 Part 1 & 2

NetdB-PRO-280: Intensity based Sound Power measurements
An efficient 2-channel turn-key solution fitting the ISO 9614 standard (Part 1 & 2) to measure the sound power characteristics of your products.

First introduced in 1996 with a dedicated and powerful software 01dB-Metravib' solution for Sound Power determination using Sound Intensity has been very successful.

Now labelled PRO-280, this system integrates the ISO-9614 standard and is made available as a dedicated package supporting dB4 platform to meet customers' needs for “handy” operation in field or laboratory conditions:

  • Very flexible
  • Most accurate
  • Full control of ISO 9614 check parameters

Key Features

Easy to operate and flexible

  • User guiding for a total support in Sound Power determination process
  • Portable and Battery Operated
  • Pre-formatted Results Data table for immediate reporting
  • ISO 9614 parameters check and errors handling with on-line tutorials and suggestions
  • Pressure and Intensity mapping
  • Calibration in amplitude and phase allowing use of different kind of Intensity probe types

Options

The PRO-280 package of hardware and software integrates the definition and execution of the power measurement and the related quantities such as:

  • Calibration check by inverting the probe
  • Stationarity check of the sound field for the point per point method
  • Integrates the dynamic calculation (during measurement) of criteria that enables validation of measurement results

Sound Intensity calibrator & calibration software are proposed as options.

PRO-280 is robot operable for increased efficiency on systematic evaluation of sound power characteristics of various test devices

Applications

Automotive, Motorbikes, Aeronautics, Railway, Ships, Space, Construction Machines, Building industry (Ground Vibrations, Environmental Data), Electric appliances/IT, Household appliances, Medical (Electro-testing, Encephalography, Electrocardiography, Electromyography)

PRO-280 Technical Specifications

Hardware features

  • Analog input channels: 4, single ended, simultaneous
  • Channel input connectors: BNC with high rigidity frame
  • Analog output channels: 1 (BNC connector)
  • Digitization: 24 bits linear
  • Maximum Sampling Rate: 52.734 kHz
  • Minimum Sampling Rate: 195.3 Hz
  • Tacho channels: 1 (31 bits)
  • Maximum Input Frequency: 380 kHz

Analog input/output characteristics

  • Input impedance: 1MOhms
  • Input range: 10V rms (-15V to +15V), 1V rms (-1.5V to +1.5V)
  • Maximum allowable voltage: ±20V (power off), ±30V (power on)
  • Overvoltage protection: ±40V
  • Sensor power supply: IEPE
  • Dynamic range: 106dB
  • THD: -90dB typically
  • External trigger: BNC connector
  • Trigger logic family: LVTTL inputs
  • Output Range: ±10V

Dimensions

  • Dimensions: 100mm (W) x 18 mm (H) x 190mm (D) excluding projections
  • Weight: 491g

Intensity Calibrator

  • Input connector: BNC socket
  • Maximum input signal: 1 V RMS
  • Frequency range: 50 Hz - 6.3 kHz
  • Frequency-intensity index: >27 dB (nomin. mic. spacing 25 mm)
  • SPL difference between channels: < 0.1 dB
  • Operating temperature Range: + 5 °C to + 40 °C
  • Dimensions: 42.2 x 50.3 x 60mm
  • Weight: 515 g
  • Accessories included: 2 × ¼" microphone adapters

Power supply features

  • Power, +5V: ±5V @0.5A

Intensity Probe

  • Microphone pair: Type 40AI-2
  • Microphone Diameter: 13.2 mm
  • Polarisation voltage: 0 V (IEPE)
  • Frequency response: IEC 60651 Type 0
  • Preamplifiers: Type 26AC - BNC Output
  • Sensitivity: 25 mV/Pa
  • Frequency & phase response: IEC 1043 Class 1
  • Dynamic range: 21 - 152 dB re. 20µPa

PC and Operating System

  • Operating System: Windows XP and higher
  • PC Processor: PII or higher, 600 MHz or higher
  • RAM: 512 Mb or higher
  • Ports: USB

* IEPE: Integrated PiezoElectric Electronic

dBFA and ISO 9614 Software

dBFA: Software to perform as Recorder - Real Time Analyzer - Post-Processing: simultaneous signal recording and real-time multiprocessing and monitoring, post processing analysis (Average 1/n octave, 1/n octave vs. time, Average FFT, FFT vs. Time, FRF...), calculation on spectra and signals, white/pink/sine/sweep sine generator (if available on hardware), color spectrogram and waterfall, tacho acquisition, signal edition, import of Teac/Sony files...
dBFA Intensity: Software option (included) for Real Time intensity calculations
dBFA Iso 9614: Software option (included) to fulfill ISO9614: Real Time Intensity and Sound Power
Iso 9614 test session: Total controls of the measurement according to the selected method and the complete use of the results according to the standard.
ISO 9614 Criteria: Calculation of specific criteria and comparison with ISO 9614 limits set in the standard according to the chosen precision class.
Results and Plotting: Plot results as Intensity and/or Pressure color maps, Data table pre-formatted to match ISO 9614 requirements, listing by point, plot and listing of results on a section of the area, plotting of the noise map and iso-curves.

Para mais informações entrar em contato conosco : comercial@01db.com.br

 

Mapa do Site | Atualizações | Menções Legais
© Copyright 2012 - ACOEM